3 Jun 2021  ·  Shen Zhang, Sufei Li, Lijun He, Jose A. Restrepo, Thomas G. Habetler ·

Interior permanent magnet synchronous machine drives are widely employed in electric traction systems and various industrial processes. However, prolonged exposure to high temperatures while operating can demagnetize the permanent magnets to the point of irreversible demagnetization. In addition, direct measurements with infrared sensors or contact-type sensors with wireless communication can be expensive and intrusive to the motor drive systems. This paper thus proposes a nonintrusive thermal monitoring scheme for the permanent magnets inside the direct-torque-controlled interior permanent magnet synchronous machines. By applying an external high-frequency rotating flux or torque signal to the hysteresis torque controller in the motor drive, the high-frequency currents can be injected into the stator windings. The permanent magnet temperature can thus be monitored based on the induced high-frequency resistance. The nonintrusive nature of the method is indicated by the elimination of the extra sensors and no hardware change to the existing system. Finally, the effectiveness of the proposed method is validated with experimental results.